To suppress and swiftly extinguish a fire in the space of origin the following functional requirements shall be met:
为抑制并迅速扑灭火源的火灾,应满足以下功能要求:
1.Fixed fire-extinguishing systems shall be installed having due regard to the fire growth potential of the protected spaces; and
应安装固定灭火系统,同时充分考虑受保护空间的火灾增长潜力。
2.Fire-extinguishing appliances shall be readily available.
灭火设备应随时可用。
Ships shall be provided with fire pumps, fire mains, hydrants and hoses complying with the applicable requirements of this regulation.
船舶应配备符合本规章适用要求的消防泵、消防总管、消火栓和水龙带。
Materials readily rendered ineffective by heat shall not be used for fire mains and hydrants unless adequately protected. The pipes and hydrants shall be so placed that the fire hoses may be easily coupled to them. The arrangement of pipes and hydrants shall be such as to avoid the possibility of freezing. Suitable drainage provisions shall be provided for fire main piping.
易受热影响而失效的材料不得用于消防主管和消火栓,除非得到适当的保护。管道和消火栓的布置应便于消防水带轻松连接。管道和消火栓的布置应避免冻结的可能性。应为消防主管管道提供适当的泄放设施。
Isolation valves shall be installed for all open deck fire main branches used for purposes other than firefighting. In ships where deck cargo may be carried, the positions of the hydrants shall be such that they are always readily accessible and the pipes shall be arranged as far as practicable to avoid risk of damage by such cargo.
隔离阀应安装在所有用于非消防目的的露天甲板消防主管分支上。在可能载运甲板货物的船舶上,消防栓的位置应使其始终易于接近,且管道应尽可能布置,以避免因此类货物而受损的风险。
The arrangements for the ready availability of water supply shall be:
供水随时可用的安排应为:
1.Of 1,000 gross tonnage and upwards such that at least one effective jet of water is immediately available from any hydrant in an interior location and so as to ensure the continuation of the output of water by the automatic starting of one required fire pump;
总吨位为1000吨及以上的船舶,必须确保从任何内部位置的消防栓立即可用至少一个有效的水射流,并确保通过自动启动一个必需的消防泵来持续供水。
2.Of less than 1,000 gross tonnage by automatic start of at least one fire pump or by remote starting from the navigation bridge of at least one fire pump. If the pump starts automatically or if the bottom valve cannot be opened from where the pump is remotely started, the bottom valve shall always be kept open; and
对于总吨位小于1000吨的船舶,至少有一台消防泵应能自动启动,或者至少有一台消防泵可以从驾驶台上远程启动。如果消防泵自动启动,或者在远程启动消防泵的地方无法打开底阀,则底阀应始终保持开启状态;并且
3.If fitted with periodically unattended machinery spaces in accordance with regulation II-1/54, the Administration shall determine provisions for fixed water fire-extinguishing arrangement for such spaces equivalent to those required for normally attended machinery spaces;
如果根据规则II-1/54配备了定期无人值守机舱,行政当局须确定该等机舱的固定水灭火装置的规定,相当于正常有人看管的机舱;
To the satisfaction of the Administration; and
为满足主管机关要求,及
With a periodically unattended machinery space or when only one person is required on watch, there shall be immediate water delivery from the fire main system at a suitable pressure, either by remote starting of one of the main fire pumps with remote starting from the navigating bridge and fire control station, if any, or permanent pressurisation of the fire main system by one of the main fire pumps, except that the Administration may waive this requirement for cargo ships of less than 1,600 gross tonnage if the fire pump starting arrangement in the machinery space is in an easily accessible position.
The diameter of the fire main and water service pipes shall be sufficient for the effective distribution of the maximum required discharge from two fire pumps operating simultaneously, except that in the case of cargo ships, the diameter need only be sufficient for the discharge of 140 m3/h.
1.Isolating valves to separate the section of the fire main within the machinery space containing the main fire pump or pumps from the rest of the fire main shall be fitted in an easily accessible and tenable position outside the machinery spaces. The fire main shall be so arranged that when the isolating valves are shut all the hydrants on the ship, except those in the machinery space referred to above, can be supplied with water by another fire pump or an emergency fire pump. The emergency fire pump, its seawater inlet, and suction and delivery pipes and isolating valves shall be located outside the machinery space.
应在机械处所外易于到达且可保持的位置安装隔离阀,以将装有主消防泵或水泵的机械处所内的消防总管部分与消防总管的其余部分分隔开。消防总管应如此布置,以便当隔离阀关闭时,船上除了上述机械处所中的消火栓外,所有消火栓都可以由另一台消防泵或应急消防泵供水。应急消防泵、其海水进口、吸入和排出管以及隔离阀应位于机械处所外。
2.A valve shall be fitted to serve each fire hydrant so that any fire hose may be removed while the fire pumps are in operation.
每个消防栓应安装一个阀门,以便在消防泵运行时拆除任何消防软管。
3.Relief valves shall be provided in conjunction with fire pumps if the pumps are capable of developing a pressure exceeding the design pressure of the water service pipes, hydrants and hoses. These valves shall be so placed and adjusted as to prevent excessive pressure in any part of the fire main system.
如果消防泵能够产生的压力超过给水管、消防栓和软管的设计压力,则应与消防泵一起提供安全阀。这些阀门的放置和调整应防止消防总系统任何部分的压力过大。
4. In tankers, isolation valves shall be fitted in the fire main at poop front in a protected position and on the tank deck at intervals of not more than 40 m to preserve the integrity of the fire main system in case of fire or explosion.
在油轮上,应在船尾前方的消防总管上安装隔离阀,并在油舱甲板上每隔不超过40米安装隔离阀,以保护位置,确保在火灾或爆炸情况下消防总管系统的完整性。
The number and position of hydrants shall be such that at least two jets of water not emanating from the same hydrant, one of which shall be from a single length of hose, may reach any part of the ship normally accessible to the passengers or crew while the ship is being navigated and any part of any cargo space when empty, any ro-ro space or any vehicle space in which latter case the two jets shall reach any part of the space, each from a single length of hose. Furthermore, such hydrants shall be positioned near the accesses to the protected spaces.
消防栓的数量和位置应确保至少有两个水柱能够达到船上通常可供乘客或船员使用的任何部分,这些水柱不能来自同一个消防栓,其中至少一个水柱应来自一段单独的软管。当船只在航行时,以及在任何空的货舱、任何滚装空间或任何车辆空间内的任何部分,这两种水柱都应能够达到,每种水柱都应来自一段单独的软管。此外,这样的消防栓应位于通往受保护空间的入口附近。
With the two pumps simultaneously delivering water through the nozzles the following minimum pressures shall be maintained at all hydrants:
当两台水泵同时通过喷嘴供水时,所有消防栓都应保持以下最低压力:
4,000 gross tonnage and upwards 0.40 N/mm2
4000总吨及以上 0.40 N/mm2
4,000 gross tonnage and upwards 0.40 N/mm2
4000总吨及以上 0.40 N/mm2
less than 4,000 gross tonnage 0.30 N/mm2;
小于4000总吨 0.30 N/mm2
6,000 gross tonnage and upwards 0.27 N/mm2
6000总吨及以上 0.27 N/mm2
less than 6,000 gross tonnage; and 0.25 N/mm2;
小于6000总吨 0.25 N/mm2
The maximum pressure at any hydrant shall not exceed that at which the effective control of a fire hose can be demonstrated.
任何消火栓的最大压力不得超过消防软管有效控制的压力。
·Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection complying with the Fire Safety Systems Code.
500总吨位及以上的船舶应提供至少一个符合消防安全系统规范的国际通岸接头。
·Facilities shall be available enabling such a connection to be used on either side of the ship.
应提供设施,使得这种接头能够在船的任一舷可用。
Sanitary, ballast, bilge or general service pumps may be accepted as fire pumps, provided that they are not normally used for pumping oil and that if they are subject to occasional duty for the transfer or pumping of oil fuel, suitable change-over arrangements are fitted.
卫生泵、压载泵、舱底泵或通用泵可以接受作为消防泵,前提是它们通常不用于抽油,并且如果它们偶尔用于调驳或抽油燃料,应安装适当的转换装置。
Ships shall be provided with independently driven fire pumps as follows:
船舶应配备如下独立驱动的消防泵:
4,000 gross tonnage and upwards at least three
4,000 总吨及以上,至少三台
less than 4,000 gross tonnageat least two
4,000 总吨以下,至少二台
1,000 gross tonnage and upwardsat least two
1,000总吨及以上,至少2台
less than 1,000 gross tonnage at least two power driven pumps, one of which shall be independently driven.
小于1000总吨的船只至少需要配备两台动力驱动泵,其中一台应独立驱动。
消防泵及消防总水管的布置
The arrangement of sea connections, fire pumps and their sources of power shall be as to ensure that:
海上连接、消防泵及其动力源的布置应确保:
1.In passenger ships of 1,000 gross tonnage and upwards, in the event of a fire in any one compartment all the fire pumps will not be put out of action; and
在1000总吨及以上的客船上,如果任何一个舱室发生火灾,所有的消防泵都不会失效;而且
2.In passenger ships of less than 1,000 gross tonnage and in cargo ships, if a fire in any one compartment could put all the pumps out of action, there shall be an alternative means consisting of an emergency fire pump complying with the provisions of the Fire Safety Systems Code with its source of power and sea connection located outside the space where the main fire pumps or their sources of power are located.
在总吨小于1000吨的客船和货船上,如果任何一个舱室发生火灾,可能会使所有泵失效,那么应有替代手段,包括一个符合《消防安全系统规则》的应急消防泵,其动力源和海水连接应位于主消防泵或其动力源所在空间之外。
In addition, in cargo ships where other pumps, such as general service, bilge and ballast, etc., are fitted in a machinery space, arrangements shall be made to ensure that at least one of these pumps, having the capacity and pressure required is capable of providing water to the fire main.
所需消防泵的总容量
The required fire pumps shall be capable of delivering for fire-fighting purposes a quantity of water, at the pressure as follows:
所需的消防泵应能够为灭火目的提供以下压力下的水量:
1.Pumps in passenger ships, the quantity of water is not less than two thirds of the quantity required to be dealt with by the bilge pumps when employed for bilge pumping; and
客船上的泵,其排量不得少于在作污水泵工作时需排量的三分之二;并且
2.Pumps in cargo ships, other than any emergency pump, the quantity of water is not less than four thirds of the quantity required under regulation II-1/35-1 to be dealt with by each of the independent bilge pumps in a passenger ship of the same dimension when employed in bilge pumping, provided that in no cargo ship, need the total required capacity of the fire pumps exceed 180 m3/h.
在货船上,除了任何应急泵之外,泵的排水量不得少于同尺寸客船中每台独立舱底泵在舱底抽水时根据规则II-1/35-1所要求处理的水量的四分之三,前提是在任何货船上,消防泵的总所需容量不超过180立方米/小时。
Each of the required fire pumps shall have a capacity not less than 80% of the total required capacity divided by the minimum number of required fire pumps but in any case not less than 25 m3/h and each such pump shall in any event be capable of delivering at least the two required jets of water. These fire pumps shall be capable of supplying the fire main system under the required conditions. Where more pumps than the minimum of required pumps are installed such additional pumps shall have a capacity of at least 25 m3/h and shall be capable of delivering at least the two jets of water.
每个所需消防泵的容量应不少于所需总容量的80%除以所需消防泵的最小数量,但无论如何不得低于25立方米/小时,并且每台这样的泵无论如何都应能够提供至少两股所需的水射流。这些消防泵应能够在所需条件下向消防总管供水。如果安装的泵比所需的最小泵数多,那么这些额外的泵应至少有25立方米/小时的排量,并且应能够提供至少两个水射流。
请稍候,系统正在生成您请求的文件