Japan PSC滞留与缺陷的检查趋势总结

Tokyo MoU (Japan)滞留与缺陷的检查趋势总结a) Detainable deficienciesFIRE SAETY - Emergency fire pump (including portable type) unable to discharge to fire hose - Pipes of fixed CO...

Tokyo MoU (Japan)滞留与缺陷的检查趋势总结a) Detainable deficiencies


FIRE SAETY

- Emergency fire pump (including portable type) unable to discharge to fire hose

- Pipes of fixed CO2 fire-extinguishing system for cargo holds corroded/holed/cut

- Fire detection control panel inoperative

- None of two(2) routes is continuously fire sheltered (Missing escape trunk)

- Fire door for escape in E/R defective(Heavy corrosion on door frame)

- Fire insulation in engine room emergency escape trunk severely damaged

- A self-closing device fitted on the frame of a combustible material (wood); Fire Integrity not in compliance with its relevant requirements

- Stairway enclosure in deck house not insulated to A Class standard on main deck, poop deck and living deck

- On deck CO2 line for cargo hold has several holes

- Malfunction of quick closing valve

ISM

- Crew is not familiar with essential shipboard procedures relating to the safety of the ship and was

unable to demonstrate proficiency in performing a satisfactory fire drill. Crew failed two

consecutive attempts of the drill evident by unfamiliarity(especially in Kobe, Osaka, Nagoya regions)

- Senior officers were not aware of their tasks and responsibilities

  • 3/O doesn't know the signals for the drill

  • Duty officer didn't ensure the proper maintenance of R/B and launching appliance

  • Crew, Members - Not familiar with how to use the launching appliance of R/B

- Insufficient knowledge for release mechanism of the lifeboat

- Installed components of M/E and G/E not verified as required by NOx technical files

- Crew's unfamiliarity with man-overboard drill

- SMS on board not properly implemented

Life Saving Appliances

- Rescue boat engine - out of order due to leaked oil

- Rescue boat recovery arrangements (winch motor) not working due to problem of limit switch

- Both sides lifeboat release hooks: not reset in proper position

- Lifeboat engines on both side not operated immediately due to shortage of batteries

- Rescue boat not stowed in a position suitable for launching and recovery

- Corrosion of lifeboat suspension ring

- Rescue boat limit switch and braking system broken

- Steering gear of lifeboat inoperative

- No evidence of lifeboats lowered and maneuvered in the water in more than a year

- Rescue boat lever inoperative

Pollution Prevention

- Oily water discharge piping leading to the overboard from the OWS was found to contain oil sludge

- Garbage Record Book not properly recorded

- Sewage Treatment Plant defective

- 15ppm Bilge Alarm not activated

- Certificate & Documentation

- Flag state endorsement of C/E expired

- NOx Parameter Record Book not properly recorded

- Safety of Navigation

- Stern light not complied with regulations

- S-VDR capsule containing server, malfunction

- GMDSS equipment not operational with DC power

- Several charts are old versions and some charts are not updated


ILL

- Lack of weather tightness for ventilation duct of cargo hold

- APT Tank air pipe closing device (float type) broken

- Hatch cover cleats missing or seized

- MLC

- Seafarer enrollment agreement expires

- 9 Crews consecutively on board more than 13 months without a vacation

Others

- Emergency generator unable to start due to starting system broken

- Some cargo operation procedures related to CSM not enough

- Anchor chain pipe on the port side in the cargo space cracked

- Holed on bulkhead of wheel house

- Pin holes on C.O.T trunk deck side wall

b) Items to be inspected thoroughly

FIRE SAETY

- Inspection of fire fighting equipment

- Installation condition of fire integrity around engine room space (close-up check during survey for new ship building and after-construction survey)

- Installation of compound on cable penetration part (close-up check during survey for new ship building)

- Emergency fire pump in proper condition

- Cleanness of E/R

- Condition of Pipes of fixed CO2 fire-extinguishing system for cargo holds

- Fire detection control panel

- Fire insulation in engine room emergency escape trunk in good condition

- Fire Integrity in compliance with its relevant requirements

ISM

- Check of essential shipboard procedures relating to safety of the ship and crew’s ability to carry out them

- Check operation of release hook of lifeboat

- Check understanding of crew for lifeboat release mechanism

- Check for special requirement for some Class A and C cargoes according to IMSBC Code and IBC procedure

- Components of M/E and G/E verified as required by NOx technical files

Life Saving Appliances

- Condition of battery in the lifeboat

- Rescue boat in correct position

- Conditions of limit switch and brake system of rescue boat

- Condition of limit switch for rescue boat

- Steering gear of lifeboat

- Official records of onboard drills/trainings as required by SOLAS

- Condition of rescue boat lever

- Certificate and Documentation

- Flag state endorsement validity

- Periodical maintenance record of NOx Parameter Record Book

ILL

- Weather tightness for ventilation duct of cargo hold

- APT Tank air pipe closing device (float type) in normal condition

- Hatch cover cleats

Pollution Prevention

- Oily water separator filter approved by oil water separator maker should be onboard

- Oil record book entry

- Safety of Navigation

- Notice marine casualty to Port authority

- Safety Navigation equipment check (Magnetic/Gyro Compass, Radar, MF/HF, etc)

- Check operation of GMDSS equipment with DC power

- Check of the latest charts and publications on board and small corrections for them

Others

- Immediate report to port authority when problems occurred

- New convention confirmation

- Newly revised Convention requirements and Certificate (IAPP, IOPP, etc.)

- Rectification inspection of deficiency for ships going within Korea-China-Japan

- Check of the cargo operation procedure related to CSM

- Condition of anchor chain pipe

- Emergency generator in working condition

- No patches or holes on bulkhead structures of cargo spaces

- No corrosion or pin holes on C.O.T trunk deck side wall